MRP-2001 is a six zone releasing fire control panel for single and dual hazard deluge and preaction applications. The MRP-2001 provides reliable fire detection, signaling and protection for commercial, industrial and institutional buildings requiring water-based releasing.
Features and Benefits

  • UL Listed to UL2572 Communication (Control Units Mass Notification Systems).
  • Modular design for maximum system flexibility and easy expansion.
  • 50 watts of 25 V audio power (expandable to 100 watts) RMS.
  • Optional amplifier can be configured as a backup in the event the primary amplifier fails. Amplifiers are independently powered to eliminate system interruption during a short circuit condition
  • Eight Command Input Circuits to activate messages 1 to 8:
    Seamless integration and control when connected to select Fire-Lite panels through the ANN/ACS (EIA-485) communication bus.
  • Speaker circuits are expandable by up to 8 outputs (With an optional circuit expander module).
  • Removable terminal blocks for ease of servicing and module replacement.
  • 2 amp Notification Appliance Circuit (NAC) output, sync generator, or follower for System Sensor, Wheelock or Gentex protocols:
    Integral supervised microphone.
  • 520HZ square wave tones can be uploaded to ECC-50/100 to meet NFPA Low Frequency requirements
  • The ECC-50BDA is an intelligent amplifier that can be configured for 50 watts or 100 watts of total audio power. It is used with the ECC-50/100(E) emergency voice evacuation system to amplify an audio message for distribution throughout a facility when additional power is required. , It provides 50 watts or 100 watts of primary power along with 50 watts of backup power and comes standard with eight built-in, fully supervised speaker circuits/zones. It can be conveniently installed near an area of protection to reduce wiring demands for speaker circuit.
    Features and Benefits

  • Each unit includes eight onboard fully supervised audio circuits
  • Any combination of up to eight ECC-50DA(E)s, ECC-125DA(E)s or ECC-50DBAs per system for a total of 1100 watts of audio power and 24 speaker circuit outputs.
  • Supports both Class A (Style Z) and Class B (Style Y) wiring.
  • Easy setup and configuration by using a simple, built-in web based programming utility on the ECC-50/100(E)
    UL2572 (Communication and Control Units Mass Notification Systems).
  • Built-in power supply and battery charger that supports up to 35AH. (For batteries larger than 18 AH, use the BB-26 or BB-55F Battery Box.)
  • ECC-50BDA is field selectable for 25 volts or 70.7 volts of operation.
    Sturdy, scratch resistant cabinet.
  • The ECC-LOC is an optional Local Operator Console that is compatible with the ECC-50/100(E) Emergency Command Center for fire protection applications and mass notification. It is part of the family of external remote consoles that allows for extending the ECC-50/100(E) display and control to remote locations within a building
    Features and Benefits

  • Provides messaging status and control of the ECC-50/100(E) primary operator console.
  • Complete operator interface that is identical to the ECC-50/100(E) that includes a built-in microphone for ALL CALL paging.
    UL 2572 (Communication and Control Units Mass Notification Systems).
  • A maximum of eight ECC-LOC’s can be connected to an ECC-50/100(E) primary operating console.
  • Built-in microphone with push-to-talk feature that can be used for ALL CALL paging.
  • Fourteen programmable message buttons that can be used to activate all speaker circuits remotely.
  • Sturdy cabinet design with a keyed lock to prevent unauthorized access. Optional thumb lock available.
  • Simple and straightforward user interface.
  • The ECC-RPU is an optional Remote Page Unit that is compatible with the ECC-50/100(E) Emergency Command Center for fire protection applications. It is part of the family of external remote consoles that allows for extending the ECC-50/100(E) display and control to remote locations within a building.
    Features and Benefits

  • Provides messaging status and control of the ECC-50/100(E) primary operator console.
  • Modular design for maximum system flexibility and easy expansion.
  • Supports both Class A (Style Z) and Class B (Style Y) wiring.
  • A maximum of eight ECC-RPU’s can be connected to an ECC-50/100(E) primary operating console.
  • Built-in microphone with push-to-talk feature that can be used for ALL CALL paging.
  • Up to fourteen programmable messaging functions that can be activated over speaker zones remotely.
  • Sturdy cabinet design with a keyed or thumb lock to prevent unauthorized access.
  • Simplistic and straightforward user interface.
  • Additional 9th button can be used to activate an optional MMF-300 monitor module installed inside the cabinet for applications such as HVAC shutdown.
  • The ECC-FFT is a firefighter telephone system that provides secure and reliable communications for firefighters. This standalone system is capable of providing supervision, annunciation and control for local and remote telephone handsets.
    Features and Benefits

  • Provides supervision control and annunciation of up to 24 remote telephone jacks.
  • Built-in Auto-program feature.
  • Simplistic and straightforward user interface.
  • Telephone circuit supervised with 4.7K, End of line resistor when wired in Style Y, Class B operation.
  • Full System status LED display.
  • Onboard SLC circuit can be wired for class A (Style 6 or Style 7) or class B (Style 4) configuration.
  • Full system status LED display.
  • Supports Multi-Phone Jack Audio Circuit supervision.
  • Onboard Form-C system trouble relay.
  • Allows simultaneous operation of up to 10 firefighter remote handsets (FHS-F) when connected to the ECC-FFT.