{"id":1855,"date":"2019-08-05T10:10:18","date_gmt":"2019-08-05T10:10:18","guid":{"rendered":"http:\/\/email-soft.net\/fire-expert\/?page_id=1855"},"modified":"2019-08-05T10:16:59","modified_gmt":"2019-08-05T10:16:59","slug":"mass-notification-2","status":"publish","type":"page","link":"https:\/\/firexpertsest.com\/index.php\/mass-notification-2\/","title":{"rendered":"Mass Notification"},"content":{"rendered":"<body><div id=\"pl-1855\" class=\"panel-layout\"><div id=\"pg-1855-0\" class=\"panel-grid panel-no-style\"><div id=\"pgc-1855-0-0\" class=\"panel-grid-cell\"><div id=\"panel-1855-0-0-0\" class=\"so-panel widget widget_sow-image panel-first-child panel-last-child\" data-index=\"0\"><div class=\"so-widget-sow-image so-widget-sow-image-default-8b5b6f678277-1855\">\n<div class=\"sow-image-container\">\n\t\t<img decoding=\"async\" src=\"https:\/\/i0.wp.com\/firexpertsest.com\/wp-content\/uploads\/2019\/08\/E3_Product.jpg?fit=215%2C275&amp;ssl=1\" width=\"215\" height=\"275\" alt=\"\" class=\"so-widget-image\" loading=\"lazy\">\n\t<\/div>\n\n<\/div><\/div><\/div><div id=\"pgc-1855-0-1\" class=\"panel-grid-cell\"><div id=\"panel-1855-0-1-0\" class=\"so-panel widget widget_text panel-first-child\" data-index=\"1\">\t\t\t<div class=\"textwidget\"><p><\/p><strong>E3 Series\u00ae Combined Fire and MNS System<\/strong><br>\nThe Gamewell-FCI, E3 Series\u00ae Broadband Emergency Voice Evacuation System and the E3 Series Broadband Networked Fire Alarm System can be combined on the common network to form a combination Fire and Mass Notification (MNS) System in accordance with the NFPA and UL Standard UL2572 requirements.\n<\/div>\n\t\t<\/div><div id=\"panel-1855-0-1-1\" class=\"widget_text so-panel widget widget_custom_html panel-last-child\" data-index=\"2\"><div class=\"textwidget custom-html-widget\">\n\t<div style=\"width:81%;\">\n\t\t\n<div class=\"tab\">\n  <button class=\"tablinks\" onclick=\"openCity(event, 'ff')\" id=\"defaultOpen\">Feature and Benefits<\/button>\n<\/div>\n\n<div id=\"ff\" class=\"tabcontent\">\n  <span onclick=\"this.parentElement.style.display='none'\" class=\"topright\">&amp;times<\/span>\n  <h3>E3 Series\u00ae Combined Fire and MNS System Features and Benefits\n<\/h3>\n<li>Listed under ANSI\/UL\u00ae Standard UL2572 for Mass Notification.<\/li>\n<li>Listed under ANSI\/UL Standard 864, 9th Edition..<\/li>\n<li>IBC Seismic Certified.<\/li>\n<li>Offers the Base Platform for the Emergency Communications System.<\/li>\n<li>Provides true, seamless and scalable integration for Fire and Mass Notification that is configured applying the E3 Series <\/li><li>building blocks using up to 122 nodes.<\/li>\n<li>Includes a cost-effective, supervised, \u201cStyle 7\u201d network wiring using a single pair of wire or fiber-optics at 625K baud.<\/li>\n<li>Contains a compact, Local Operating Console (LOC) that is designed for installation in lobbies, doorways and hallways allowing quick access to do the following:<\/li>\n<li>Broadcast MNS announcements.<\/li>\n<li>View the System Status messages.<\/li>\n<li>Designed with a user-friendly, color touchscreen display that provides all Fire and MNS Events at all locations.<\/li>\n<li>Installs a simple configuration of multiple LOCs with expandability from 16 to 64 programmable switches for status, message activation and control.<\/li>\n<li>Uses fully supervised wiring outputs for outstanding protection.<\/li>\n<li>Broadcasts a digital, audio, resonant sound to meet the intelligibility requirements.<\/li>\nSupports each audio node with up to 150 watts of audio power, provided by three, 50 watt amplifiers in addition to providing 50 watts of standby power.\n<li>Stores distributed, digital message storage at each audio amplifier location for maximum survivability.<\/li>\n<li>Applies Advanced Boolean Logic programming to reduce equipment costs by providing software solutions to complex configurations using the following devices.<\/li>\n<li>Timers<\/li>\n<li>Sequencing<\/li>\n\t<li>Schedulers<\/li>\n<\/div>\n\n<script>\nfunction openCity(evt, cityName) {\n  tabcontent = document.getElementsByClassName(\"tabcontent\");\n  for (i = 0; i < tabcontent.length; i++) {\n    tabcontent[i].style.display = \"none\";\n  }\n  tablinks = document.getElementsByClassName(\"tablinks\");\n  for (i = 0; i < tablinks.length; i++) {\n    tablinks[i].className = tablinks[i].className.replace(\" active\", \"\");\n  }\n  document.getElementById(cityName).style.display = \"block\";\n  evt.currentTarget.className += \" active\";\n}\n\n\/\/ Get the element with id=\"defaultOpen\" and click on it\ndocument.getElementById(\"defaultOpen\").click();\n<\/script>\n\t<\/div>\n<\/div><\/div><\/div><\/div><div id=\"pg-1855-1\" class=\"panel-grid panel-no-style\"><div id=\"pgc-1855-1-0\" class=\"panel-grid-cell\"><div id=\"panel-1855-1-0-0\" class=\"so-panel widget widget_sow-image panel-first-child panel-last-child\" data-index=\"3\"><div class=\"so-widget-sow-image so-widget-sow-image-default-8b5b6f678277-1855\">\n<div class=\"sow-image-container\">\n\t\t<img decoding=\"async\" src=\"https:\/\/i0.wp.com\/firexpertsest.com\/wp-content\/uploads\/2019\/08\/Screenshot_5.png?fit=156%2C236&amp;ssl=1\" width=\"156\" height=\"236\" alt=\"\" class=\"so-widget-image\" loading=\"lazy\">\n\t<\/div>\n\n<\/div><\/div><\/div><div id=\"pgc-1855-1-1\" class=\"panel-grid-cell\"><div id=\"panel-1855-1-1-0\" class=\"so-panel widget widget_text panel-first-child\" data-index=\"4\">\t\t\t<div class=\"textwidget\"><p><\/p><strong>FireVac\u00aeIV Emergency Voice Evacuation System<\/strong><br>\nAn automatic combination fire alarm and emergency voice evacuation system when combined with a fire alarm control panel. It\u2019s ideal for installations requiring voice evacuation of places of assembly such as churches, cafeterias, auditoriums, etc. The power output available from the FireVac\u00aeIV is a cost effective solution to smaller voice evacuation applications such as, assisted living facilities, dormitories, motels, and hotels.\n<\/div>\n\t\t<\/div><div id=\"panel-1855-1-1-1\" class=\"widget_text so-panel widget widget_custom_html panel-last-child\" data-index=\"5\"><div class=\"textwidget custom-html-widget\">\n\t<div style=\"width:81%;\">\n\t\t\n<div class=\"tab\">\n  <button class=\"tablinks\" onclick=\"openCity(event, 'l')\" id=\"defaultOpen\">Feature and Benefits<\/button>\n<\/div>\n\n<div id=\"l\" class=\"tabcontent\">\n  <span onclick=\"this.parentElement.style.display='none'\" class=\"topright\">&amp;times<\/span>\n  <h3>FireVac\u00aeIV Emergency Voice Evacuation System Features and Benefits\n<\/h3>\n<li>Compatible with any UL Listed fire alarm control panel.<\/li>\n<li>50 watt power output.<\/li>\n<li>25 or 70.7 (optional) VRMS power-limited operation.<\/li>\n<li>Integral message repeater.<\/li>\n<li>Eight (8) DIP-switch selectable tones:<\/li>\n<li>ANSI Cadence<\/li>\n<li>Alert Tone<\/li>\n<li>March Code<\/li>\n<li>Hi-Lo<\/li>\n<li>California Code<\/li>\n<li>ANSI Whoop<\/li>\n<li>Steady<\/li>\n<li>Continuous Whoop<\/li>\n<li>Optional FVIV-ZS provides four Style Y or Z (Class A or B) speaker circuits.<\/li>\n<li>Auxiliary audio input.<\/li>\n<li>Form \u201cC\u201d trouble and alarm relay outputs.<\/li>\n<li>Remote microphone module for all-call paging.<\/li>\n\t<li>Single channel operation.<\/li>\n<\/div>\n\n<script>\nfunction openCity(evt, cityName) {\n  tabcontent = document.getElementsByClassName(\"tabcontent\");\n  for (i = 0; i < tabcontent.length; i++) {\n    tabcontent[i].style.display = \"none\";\n  }\n  tablinks = document.getElementsByClassName(\"tablinks\");\n  for (i = 0; i < tablinks.length; i++) {\n    tablinks[i].className = tablinks[i].className.replace(\" active\", \"\");\n  }\n  document.getElementById(cityName).style.display = \"block\";\n  evt.currentTarget.className += \" active\";\n}\n\n\/\/ Get the element with id=\"defaultOpen\" and click on it\ndocument.getElementById(\"defaultOpen\").click();\n<\/script>\n\t<\/div>\n<\/div><\/div><\/div><\/div><\/div><\/body>","protected":false},"excerpt":{"rendered":"<p>E3 Series\u00ae Combined Fire and MNS System The Gamewell-FCI, E3 Series\u00ae Broadband Emergency Voice Evacuation System and the E3 Series Broadband Networked Fire Alarm System can be combined on the common network to form a combination Fire and Mass Notification (MNS) System in accordance with the NFPA and UL Standard UL2572 requirements. FireVac\u00aeIV Emergency Voice [&hellip;]<\/p>\n","protected":false},"author":1,"featured_media":0,"parent":0,"menu_order":0,"comment_status":"closed","ping_status":"closed","template":"","meta":{"om_disable_all_campaigns":false,"_monsterinsights_skip_tracking":false,"_monsterinsights_sitenote_active":false,"_monsterinsights_sitenote_note":"","_monsterinsights_sitenote_category":0,"footnotes":""},"class_list":["post-1855","page","type-page","status-publish","hentry"],"jetpack_sharing_enabled":true,"_links":{"self":[{"href":"https:\/\/firexpertsest.com\/index.php\/wp-json\/wp\/v2\/pages\/1855"}],"collection":[{"href":"https:\/\/firexpertsest.com\/index.php\/wp-json\/wp\/v2\/pages"}],"about":[{"href":"https:\/\/firexpertsest.com\/index.php\/wp-json\/wp\/v2\/types\/page"}],"author":[{"embeddable":true,"href":"https:\/\/firexpertsest.com\/index.php\/wp-json\/wp\/v2\/users\/1"}],"replies":[{"embeddable":true,"href":"https:\/\/firexpertsest.com\/index.php\/wp-json\/wp\/v2\/comments?post=1855"}],"version-history":[{"count":8,"href":"https:\/\/firexpertsest.com\/index.php\/wp-json\/wp\/v2\/pages\/1855\/revisions"}],"predecessor-version":[{"id":1864,"href":"https:\/\/firexpertsest.com\/index.php\/wp-json\/wp\/v2\/pages\/1855\/revisions\/1864"}],"wp:attachment":[{"href":"https:\/\/firexpertsest.com\/index.php\/wp-json\/wp\/v2\/media?parent=1855"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}